Overview
Specifications
Documents
Product Overview
Fire-Lite's MS-9600LS(E) and MS-9600UDLS(E) are compact, cost effective, intelligent addressable FACPs (Fire Alarm Con- trol Panels) with an extensive list of powerful features. The combination of FireLite's newer series devices and legacy 300 Series devices, along with the MS-9600LS(E) or MS-9600UDLSE FACP, offer the latest in fire protection tech- nology. LiteSpeedTM is a patented technology that polls 10 devices at a time looking for new or different information. When new information is found at a specific address, the sys- tem polls that device several times for any new data. This improvement allows a fully loaded panel with up to 636 devices to report an incident and activate the notification cir- cuits in under 10 seconds. With this new polling scheme, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet per loop. Each Signaling Line Cir- cuit (SLC) loop supports up to 159 addressable detectors including photoelectric, photoelectric with heat, beam, ioniza- tion, photoelectric duct, fixed heat, fixed heat with rate-of-rise, and fixed high-heat detectors. It also supports up to 159 addressable modules including monitor (two-wire detector, normally open devices), dual-monitor functions (two monitor circuits from one module, two addresses used), multimonitor (multiple monitor circuits from one module, multiple addresses used), control (for Notification Appliance Circuits), and relay (two Form-C) modules.The FLPS-7 power supply is a separate board while all other electronics are contained on a single main circuit board. Both boards are mounted to a quick-removable chassis and housed in a metal cabinet. The backbox can be installed allowing field wiring to be pulled. When construction is completed, the chas- sis with the electronics can be quickly installed with two bolts. The MS-9600UDLS(E) includes a factory-installed DACT-UD2 Digital Alarm Communicator Transmitter. The DACT transmits system status (alarm, troubles, AC loss, etc.) to a Central Sta- tion via internet (optional IPDACT installed) or the public switched telephone network.Optional modules, which plug into the main circuit board, are available for special functions. Available accessories include LED, graphic and LCD annunciators, reverse polarity/city box transmitter, digital alarm communicator/transmitter, SLC expansion module, local and remote upload/download soft- ware and remote power expansion.FM APPROVED to UL ANSI 864.
Main Features
- 6 A switching power supply
- Easy mount chassis
- Large enclosure allows 18Ah batteries
- 1 Plug-in communicator standard with MS-9600UDLS/E
- Optional IPDACT Internet Protocol Digital Alarm Communicator/ Transmitter
- Four Style Y (Class B) or two Style Z (Class A) NAC circuits.
General Information
Name: Fire-Lite MS-9600LSE Addressable Fire Alarm Control Panel with Optional Second Loop, 220/240 VAC Input
Category: Fire-Lite Alarms by Honeywell, Fire, Fire Control Panels, Fire Alarm Control Panels
UPC Code:
Country of Origin: United States. Country of origin is subject to change.
Specifications
-
ADI Part Number FL-MS9600LSE Brand Name Fire-Lite Manufacturer Honeywell International, Inc Manufacturer Part Number MS-9600LSE Product Model MS-9600LS(E) Product Name Intelligent Addressable FACP with Optional 2nd Loop Product Type Fire Alarm Control/Communicator Â
-
Connectivity Technology Wired Number of Devices Supported per Zone 318 Number of Events Log 1000 Panel Control Type Addressable Â
-
Battery Chemistry Sealed Lead Acid (SLA) Battery Voltage 27.6V DC Â
-
Display Type LCD Â
-
Serial Yes Â
-
Sensor Connectivity Wired Â
-
Depth 5" Width 19" Â
-
Input Voltage 120 V AC, 230 V AC Â
-
Certifications & Standards - ULC: S624 (MS-9600LSC only; see DF-60438)
- FM APPROVED: to UL ANSI 864
- CSFM: 7170-0075:217
- MEA: 87-08-E
Â