Control Panel Modules
Filter Results
Showing 1 - 28 of 237
content loaded
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
SK-MONITOR|SK-MONITOR
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
SK-CONTROL|SK-CONTROL
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- 15 to 32V DC
- Built-in type identification automatically identifies these devices to the control panel
- Internal circuitry and relay powered directly by two-wire SLC loop
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- 15 to 32V DC
- Built-in type identification automatically identifies this device as a monitor module to the control panel.
- Powered directly by two-wire SLC loop. No additional power required.
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- 15-32V DC
- Supervises a Style B (Class B) circuit of dry-contact input devices
- Compact design allows mounting in a single-gang box behind the device it monitors
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Two sets of Form C contacts
- Rotary address switches for fast installation
- Relay programming is completely flexible – can be mapped to zone conditions
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Provides Two Independent Two Wire Initiating Device Circuits at Two Separate, Consecutive Addresses
- Capable of Monitoring Normally Open Contact Fire Alarm and Supervisory Devices
- Module has a Single Panel Controlled LED
Sign In for Dealer Pricing
Sign In for Dealer Pricing
SK-MONITOR|SK-MONITOR
Key Features
- Single contact monitor
- Support for Class A and Class B wiring
- Fully supervised
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- CMF-300 may be used to switch 24V NAC power
- A trouble condition on the external power supplyWill never interfere with the rest of the system
- Built-in type identification automatically identifies this device to the control panel
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- 1 Class B monitoring input
- SLC Class A, Class X and Class B
- Mounts in a standard 4" or double gang box
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- MMF-300(A) is a standard-sized module that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices.
- MMF-301(A) is a miniature monitor module a mere 1.3" (3.302cm) used to supervise a Style B (Class B) circuit of dry-contact input devices.
- MMF-302(A) is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit.
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Optional card that provides the ES-1000X Series Fire Alarm Control Panels with additional SLC communication loops
- A maximum of two SLC3-LS cards may be installed on the Fire Alarm Control Panel
- Offering a total of 3 SLC loops and 954 points in the system
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Easy mount chassis
- Large enclosure allows 18 A-hour batteries
- 7 A switching power supply
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Powered by SLC loop directly, no external power required
- Integral LED blinks to indicate normal condition Illuminates steady when short circuit condition is detected
- Mounts in standard junction boxes
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Six addressable Style B (Class B) or three addressable Style D (Class A) outputs that function as notification appliance/telephone circuits.
- Removable plug-in terminal blocks.
- Status indicators for each point.
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Plugs into Main Controller Board
- Convert five Class B Initiating Device Circuits to Class A
- Convert two Class B Notification Appliance Circuits to Class A
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Ten Addressable Class B or Five Addressable Class a Initiating Device Circuits
- Status Indicators for Each Point
- Flex Mounting Options
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Cascading Mesh Wireless Technology
- Any wireless device can be added to act as a repeater
- Standard-sized module that supervises either a Style D or Style B circuit of dry-contact input devices
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Circuits are Configured Through theWeb-Based Progra mming Utility
- Removable terminal blocks for ease of servicing and module replacement
- Modular design for system flexibility and easy expansion
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- ANN-I/O connects to the ANN-Bus terminal on the FACP and requires minimal programming
- Each ANN-I/O module drives up to 40 LEDs
- programmable to indicate activity for points or zones
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- ANN-RLY connects to the ANN-BUS terminal on the FACP and requires minimal programming
- Provides 10-programmable Form-C relays
- Ten Form-C relays can be programmed for various functions; Alarm, Trouble, Supervisory, AC Loss,Waterflow Delay, Input Zones and Silenceable Alarm
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- UL/ULC Listed
- Can be plugged into connectors J3 and J5 or J4 and J6 on the MS-4 main circuit board
- Can be plugged into connectors J3 & J5 on the MS-2 main circuit board
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- SLC Standby & Alarm Current: .27mA max. at 24V DC with communication
- End-of-Line Resistance: 3.9kW
- Standby Current: 12mA at 24V DC (nominal)
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
SK-CONTROL|SK-CONTROL
Key Features
- Flexible solution for adding notification circuits where needed
- Rotary address switches for fast installation
- Support for Class B (Style Y) or Class A (Style Z) wiring
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Perfect for useWhen connecting compatible panels using fiber optic cable and/or copperWire for improved multi-site management and lower monthly monitoring costs
- Flexibility - networked FACPs can connect in Styles 5 or 7 configurations
- Can also be used with a variety ofWire types, such as standard unshielded or twisted-pair copperWire
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- 10 contact monitor
- Support for Class A and Class B wiring
- Fully supervised
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Adds 99 SK Modules and 99 SK Detectors or 127 SD Addressable Devices to a 5820XL or 5820XL EVS Addressable Fire Alarm Control Panel
- Three 5815XLs per system
- 5815XL SLCs have same functionality as the 5820XL/EVS, including Style 6 (Class A) configuration
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Panel controlled status LED that flashes green in normal state and is solid red in alarm
- Isolates short circuits on an SLC loop
- Protects the modules on the SLC loop so other devices continue to operate
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Simple plug-in card installation
- Connect compatible panels using fiber optic cable for improved multi-site management and lower monthly monitoring costs
- Use single and multi-mode modules on the same network card for added design flexibility
Sign In for Dealer Pricing
Sign In for Dealer Pricing



























