Product Overview

M Series Type 2 Surge Panel, 600VAC, ThreePhase Delta, Max Surge Current Rating of 130kA per Mode/260kA per Phase, 200kA Short Circuit Current Rating (SCCR), 20kA I-nominal (ln) Rating, NEMA 4 Rated Enclosure, Thermally Protected MOVs, VPR Performance Data L-G; 2000, L-L; 2000, Maximum Continuous Operating Voltage (MCOV); 680V, Plastic Enclosure, LED Status Monitoring, Audible Alarm, UL 1449 Listed, UL 1283 EMI/RFI Filtering, Approximate Lead Length 28.

Main Features

  • Leviton surge protective devices (SPDs) divert damaging voltage transients, or surges, away from electronic equipment
  • Ideal for Point-Of-Entry Or Main Service Entrance Installations, the M series offers greater protection in a wide variety of voltage configurations
  • Code Compliant - in 2020, Article 23.67 of the National Electrical Code (NEC) updates required all services supplying dwelling units to be provided with a surge protective device (SPD), as an integral part of equipment or located immediately adjacen. The SPD must be a Type 1 or Type 2 SPD. The 2023 code expanded the requirements to dormitory units, guest rooms and guest suites of hotels and motels, and areas of nursing homes and limited-care facilities used exclusively as patient sleeping rooms
  • The maximum amount of current the device is capable of diverting to ground during a single surge event without performance degradation of more than 10%
  • Higher values are better
  • The amount of current the device can divert to ground 15 times under specific test conditions and maintain performance levels
  • The maximum voltage a surge protector will let through to connected devices
  • Lower values are better
  • The maximum current a device or system can safely withstand for a specified time, or until a specified fuse or circuit breaker opens and clears the circuit

General Information

Name: Leviton M3600-DB Type 2 Surge Protective Device, 600VAC, Three Phase Delta
Category: Leviton, Batteries & Power Supplies, Power Strips & Surge Protectors, Surge Protection Modules
UPC Code: 78477000328
Country of Origin: . Country of origin is subject to change.

Specifications