Product Overview
The HW-TG7FS Fire Series combines Telguard’s 5G LTE-M model TG-7FS Fire Alarm Communicator with the powerful capabilities of Honeywell’s Connected Life Safety Services (CLSS) Cloud. The CLSS-Enabled 5G LTE-M Fire Alarm Communicator transmits alarm signals from the fire panel over the 5G/LTE-M networks of AT&T (HW-TG7FS-A) and Verizon (HW-TG7FS-V) to the designated monitoring station while leveraging connectivity with CLSS to enable powerful tools. Compliant with 2019 and earlier editions of NFPA 72, the CLSS LTE Fire Communicator can serve as the sole communication path. For existing installations, all landlines dedicated to the master control unit can be replaced with a single CLSS 5G/LTE-M Fire Communicator because of its 5 or 60-minute supervision modes
General Information
Name : Honeywell Power HW-TG7FS-V CLSS-Enabled LTE Commercial Fire Alarm Communicator, Verizon , Honeywell Power
Category : Alarm Communicators
UPC Code : 702054304393
Country of Origin : United States. Country of origin is subject to change.
Specifications
General Information
ADI Part Number : 0H-HWTG7FSV
Brand Name : Honeywell
Connectivity Technology : Wired, Wireless
Manufacturer : Honeywell International, Inc
Manufacturer Part Number : HW-TG7FS-V
Product Model : HW-TG7FS-V
Product Name : HW-TG7FS-V: CLSS 5G/LTE-M Fire Communicator for Verizon
Product Series : HW-TG7
Product Type : Alarm Communicator
Technical Information
Cellular Generation : 5G LTE-M
Battery Information
Battery Voltage : 24 V DC
Battery Voltage (V DC) : 24
Network & Communication
Sensor Connectivity : Wired, Wireless
Physical Characteristics
Color : Red
Depth : 3.5"
Depth (mm) : 88.9
Height : 7.5"
Height (mm) : 190.5
Shipping Weight (Approximate) : 6.5 lb
Width : 11.5"
Width (mm) : 292.1
Power Description
Input Voltage : 24V DC
Input Voltage (V DC) : 24
Miscellaneous
Compatibility : Verizon
Features : 60- or 5-minute cellular supervision available; 180-seconds available in Canada, Alarm format support for contact ID, SIA2pulse (3x1, 4x2), modem lle, IIIa, and DMP, Allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration, Automatic self-test (daily or 6-hour), Available relay output for tripping the alarm control panel when a trouble condition occurs, Certified for use on the AT&T and Verizon LTE networks, Falls back to 3G/4G if an LTE network is not available, for extended network coverage, Integration with CLSS enables monitoring of event transmission data & managementof device inventory from the CLSS mobile app and web portal (available only when using Contact ID and pointbased reporting), Locking, red metal enclosure, Meets UL 864 requirements for sole primary or backup path communications, Minimizes false alarms by providing dual paths for self-tests, Telephone line monitor built-in, with standard line security, Two programmable supervisory trip outputs