content loaded

Altronix MAXIMAL11FDV Access Power Controller with Power Supply / Chargers, 16 PTC Class 2 Relay Outputs, Dual 12/24VDC P/S at 3.5A Each, FAI, LinQ2 Ready, 220VAC, BC800 Enclosure
MAXIMAL11FDV|AX-MAXIMALDV
Altronix MAXIMAL11FDV Access Power Controller with Power Supply / Chargers, 16 PTC Class 2 Relay Outputs, Dual 12/24VDC P/S at 3.5A Each, FAI, LinQ2 Ready, 220VAC, BC800 Enclosure
MAXIMAL11FDV|AX-MAXIMALDV
Key Features
- Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs
- Normally open (NO) or normally closed (NC) dry contact input
- Polarity reversal input from FACP signaling circuit
Key Features
- Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs
- Normally open (NO) or normally closed (NC) dry contact input
- Polarity reversal input from FACP signaling circuit
Sign In for Dealer Pricing
Become an ADI CustomerKey Features
- Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs
- Normally open (NO) or normally closed (NC) dry contact input
- Polarity reversal input from FACP signaling circuit

Altronix
Altronix MAXIMAL11FDV Access Power Controller with Power Supply / Chargers, 16 PTC Class 2 Relay Outputs, Dual 12/24VDC P/S at 3.5A Each, FAI, LinQ2 Ready, 220VAC, BC800 Enclosure
MAXIMAL11FDV | AX-MAXIMALDV
Please sign in to view pricing and availability and to add to cart.
Overview
Specifications
Documents
Product Overview
Introducing the Altronix MAXIMAL11FDV Access Power Controller, designed to efficiently manage and distribute power to your access control systems and accessories. This robust unit converts a 220V AC input into sixteen independently controlled 12V DC or 24V DC outputs, all protected by PTC. It seamlessly integrates with various access control devices, including mag locks and electric strikes, and supports both fail-safe and fail-secure modes. The FACP Interface allows for emergency egress and alarm monitoring, ensuring safety and reliability. With selectable fire alarm disconnect features, this controller is a must-have for any security setup. Enhance your security system today with the Altronix MAXIMAL11FDV!
Main Features
- Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs
- Normally open (NO) or normally closed (NC) dry contact input
- Polarity reversal input from FACP signaling circuit
- Alarm output relay indicates that FACP input is triggered (form "C" contact rated at 1A 28V DC).
- AC fail supervision (form "C" contacts)
- Notification trigger is selectable for 30 seconds (factory set) or 2 hours
- Low battery and battery presence supervision (form "C" contact)
- Capacity: 12AH/12V DC (4 within enclosure); 40AH/65AH (requires separate enclosure)
- Type Sealed lead acid or gel type
- Failover: Upon AC loss, instantaneous
General Information
Name: Altronix MAXIMAL11FDV Access Power Controller with Power Supply / Chargers, 16 PTC Class 2 Relay Outputs, Dual 12/24VDC P/S at 3.5A Each, FAI, LinQ2 Ready, 220VAC, BC800 Enclosure
Category: Altronix, Batteries & Power Supplies, Power Supplies & Boards, Access Power Controllers
UPC Code:
Country of Origin: . Country of origin is subject to change.
Specifications
-
ADI Part Number AX-MAXIMALDV Brand Name Altronix Manufacturer Altronix Corporation Manufacturer Part Number MAXIMAL11FDV Product Line Maximal Product Model MAXIMAL11FDV Product Name Access Power Controller With Power Supply/Chargers, 16 PTC Class 2 Relay Outputs, Dual 12/24V DC P/S at 3.5A each, FAI, LinQ2 Ready, 220V AC, BC800 Enclosure Product Series Maximal Product Type Access Power Controller Sector Access Control Weight 33.4lb
-
Number of Doors 16 Output Voltage 12V DC, 24V DC
-
NDAA Compliant Yes
-
Operating Temperature (T-T) 32-120°F Storage Temperature (T-T) -4-158°F
-
Depth 6.25" Height 26" Width 19"
-
Input Voltage 220V AC
-
Limited Warranty Lifetime
-
Environmental Certification RoHS Features AC fail supervision (form "C" contacts), Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC)., Capacity: 12AH/12VDC (4 within enclosure); 40AH/65AH (requires separate enclosure), Failover: Upon AC loss, instantaneous, Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs, Low battery and battery presence supervision (form "C" contact), Normally open (NO) or normally closed (NC) dry contact input, Notification trigger is selectable for 30 seconds (factory set) or 2 hours, Polarity reversal input from FACP signaling circuit, Type: Sealed lead acid or gel type Indoor/Outdoor Indoor