Fire-Lite MS-5UD-3E Fire Alarm Control Panel, 5-Zone Conventional Fire Control Panel with 3A Power Supply, 220V

MS-5UD-3E|FL-MS5UD3E

Fire-Lite MS-5UD-3E Fire Alarm Control Panel, 5-Zone Conventional Fire Control Panel with 3A Power Supply, 220V

MS-5UD-3E|FL-MS5UD3E
Key Features
What's Included
  • Built-in Keypad
Key Features
What's Included
  • Built-in Keypad

Sign In for Dealer Pricing

Become an ADI Customer
Fire Lite
Key Features
What's Included
  • Built-in Keypad
Fire-Lite Alarms by Honeywell

Fire-Lite MS-5UD-3E Fire Alarm Control Panel, 5-Zone Conventional Fire Control Panel with 3A Power Supply, 220V

MS-5UD-3E | FL-MS5UD3E

Please sign in to view pricing and availability and to add to cart.

Accessories

Batteries
Ultratech UT12120 General Purpose Battery
ADI # IM-12120
MODEL # IM-12120
Sign In for Dealer Pricing
Batteries
Ultratech IM Battery
ADI # IM-1272F1
MODEL # IM-1272F1
Sign In for Dealer Pricing
Aerosol Detector Testers
W Box 0E-SMOKETEST Aerosol Smoke Detector Tester
ADI # 0E-SMOKETEST
MODEL # 0E-SMOKETEST
Sign In for Dealer Pricing
Smoke & CO Detectors
Image of 0E-SMKCODTCR
ADI # 0E-SMKCODTCR
MODEL # 0E-SMKCODTCR
Sign In for Dealer Pricing
Smoke Detectors
Image of 0E-SMKDTCR
ADI # 0E-SMKDTCR
MODEL # 0E-SMKDTCR
Sign In for Dealer Pricing
Overview
Specifications
Documents

Product Overview

The MS-5UD-3(E) is a five-zone FACP (Fire Alarm Control Panel) and the MS-10UD-7(E) is a ten-zone FACP. These control panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional buildings. Both panels include built-in communicators for Central Station Service and remote upload/download.

Each of these FACPs is compatible with System Sensor's microprocessor-based i3 series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory "freeze" signal when the ambient temperature falls below the detector rating. Additionally, both the MS-5UD-3 and MS10UD-7 are compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches, and other normally-open contact devices. Refer to the FireLite Device Compatibility Document for a complete listing of compatible devices.

Outputs include four NACs (Notification Appliance Circuits), three programmable Form-C relays (factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special application resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity.

Activation of a compatible smoke detector or any normallyopen fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function.

New options include a UL listed printer, PRN-6F and FireLite's IPDACT Internet Monitoring module. The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line.

NOTE: The MS-5UD-3E and MS-10UD-7E offers the same features as the MS-5UD-3 and MS-10UD-7 but allow connection to 240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 120 VAC and the 240 VAC versions of these panels.

NOTE: For ULC-listed models, see DF-60440.

Features

  • Listed to UL Standard 864, 9th edition.
  • Built-in DACT (Digital Alarm Communicator/Transmitter).
  • Style B (Class B) IDC (Initiating Device Circuit)
    • MS-5UD-3 - five IDCs.
    • MS-10UD-7 - ten IDCs.
  • Style Y (Class B) NAC (Notification Appliance Circuit) - special application power
    • MS-5UD-3 - four NACs
    • MS-10UD-7 - four NACs.
  • Notification Appliances may be programmed as
    • Silence Inhibit.
    • Auto-Silence.
    • Strobe Synchronization for System Sensor, Wheelock, Gentex, Faraday, or Amseco devices.
    • Selective Silence (horn-strobe mute).
    • Temporal or Steady Signal.
    • Silenceable or Nonsilenceable.
  • Optional CAC-5X Style Z (Class A) Converter Module for NACs and IDCs (2 required for MS-10UD-7).
  • Form-C Relays for Alarm, Trouble and Supervisory - Contact Ratings 2.0 A@ 30 VDC or 0.5 A @ 30 VAC (resistive).
  • 3.0 A total system current for MS-5UD-3.
  • 7.0 A total system current for MS-10UD-7.
  • Optional Dress Panel DP-51050
  • Optional Trim Ring TR-CE for semi-flush mounting.
  • 24 volt operation.
  • Low AC voltage sense.
  • Alarm Verification.
  • PAS (Positive Alarm Sequence).

Main Features

  • Built-in Keypad

General Information

Name: Fire-Lite MS-5UD-3E Fire Alarm Control Panel, 5-Zone Conventional Fire Control Panel with 3A Power Supply, 220V
Category: Fire-Lite Alarms by Honeywell, Fire, Fire Control Panels, Fire Alarm Control Panels
UPC Code: 783008109035
Country of Origin: . Country of origin is subject to change.

Specifications

Product Documents and Resources