Edwards Signaling SD-ST SD Series SuperDuct 4-Wire Smoke Sensor with Terminals
Edwards Signaling SD-ST SD Series SuperDuct 4-Wire Smoke Sensor with Terminals
Edwards Signaling SD-ST SD Series SuperDuct 4-Wire Smoke Sensor with Terminals
SD-STÂ |Â ED-SDST
Please sign in to view pricing and availability and to add to cart.
Product Overview
Less than two inches deep, SuperDuct four-wire smoke detectors are suitable for installation in ductwork, where space is limited. SuperDuct detectors feature removable dust filters, conformally coated circuit boards, and optional water-resistant gaskets to keep contaminants away from components. They include industry standard sampling tube mounting holes to simplify retrofit applications.
SuperDuct detectors use differential sensing to prevent gradual environmental changes from triggering false alarms. A rapid change in environmental conditions, such as smoke from a fire, causes the detector to automatically signal an alarm condition but dust and debris accumulated over time does not change alarm sensitivity.
The relay output may be configured for operation independent of the duct detector. A dedicated dirty/trouble LED on each unit offers immediate at-a-glance information even when the cover is closed.
The controller can be installed up to 15 feet from detector and one controller can support up to two detectors. Up to 15 controllers can be interconnected for multiple fan shutdown.
Remote Test/Reset stations are available to provide alarm testing and indication from a remote location. Two-wire SuperDuct detectors are also compatible with 5956A remote alarm LEDs.
Main Features
- Less than 2" deep
- PCB mounted photoelectric detector with on-board intelligence
- Environmental compensation with patented differential sensing
- 100 ft./min. to 4,000 ft./min. air velocity rating
- Standard RJ45 modular interconnection
- Status LEDs visible through clear cover
- Cover tamper reed switch for added security
- Standard sampling tube and mounting holes
- Install in tandem with the controller assembly, or remotely from it
- Magnet-activated test/dirty/reset switch
General Information
Specifications
-
ADI Part Number ED-SDST Brand Name Edwards Signaling Manufacturer Carrier Manufacturer Part Number SD-ST Product Name Smoke Detector Duct Installation Product Type Smoke Detector Duct Installation Kit Â
-
Device Supported Smoke Detector Â
-
Input Current 2 A Input Current (A) 2 Input Voltage 120V AC, 18V DC, 230V AC, 24V DC, 30V DC Input Voltage (V AC) 120, 230 Input Voltage (V DC) 18, 24, 30 Â