Product Overview
The MRP-2001 is a six-zone FACP for single and dual hazard deluge and preaction applications. The MRP-2001 provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring water-based releasing. The MRP-2001 is compatible with System Sensor's i3 detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory 'freeze' signal when the ambient temperature falls below the detector rating of approximately 45°F (7.22°C). In addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Refer to the Fire?Lite Device Compatibility Document for a complete listing of compatible devices.
Four outputs are programmable as NACs (Notification Appliance Circuits) or releasing circuits. Three programmable Form-C relays (factory programmed for Alarm, Trouble and Supervisory) and 24 VDC special application resettable and non-resettable power outputs are also included on the main circuit board. The MRP-2001 supervises all wiring, AC voltage, battery charger and battery level.
Activation of a compatible smoke detector or any normallyopen fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicator, display alarm information on the panel's LCD, sound the piezo sounder at the FACP, activate the FACP alarm relay and operate an optional module used to notify a remote station or initiate an auxiliary control function.
The MRP-2001E offers the same features as the MRP-2001 but allows connection to 240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 120 VAC and 240 VAC versions of the panels.
General Information
Name : Fire-Lite MRP-2001E Six-Zone 24V Deluge-Preaction Control Panel for Single and Dual Hazard Deluge and Preaction Applications, 240V AC , Fire-Lite Alarms by Honeywell
Category : Fire Alarm Control Panels
UPC Code : 783008109271
Country of Origin : United States. Country of origin is subject to change.
Specifications
General Information
ADI Part Number : FL-MRP2001E
Brand Name : Fire-Lite Alarms by Honeywell
Manufacturer : Honeywell International, Inc
Manufacturer Part Number : MRP-2001E
Product Model : MRP-2001E
Product Name : MRP-2001E Fire Alarm Control Panel
Product Type : Fire Alarm Control Panel
Technical Information
Number of Standard Zones : 6
Battery Information
Battery Chemistry : Sealed Lead Acid (SLA)
Battery Voltage : 27.6 V DC
Battery Voltage (V DC) : 27.6
Network & Communication
Sensor Connectivity : Wired
Physical Characteristics
Depth : 0.7"
Depth (mm) : 18.288
Height : 19.3"
Height (mm) : 489.204
Width : 16.8"
Width (mm) : 427.228
Power Description
Input Voltage : 230V AC
Input Voltage (V AC) : 230
Miscellaneous
Additional Information : <ul> <li>System Sensor i3 Series Detectors</li> </ul> <p><b>Fire-Lite:</b></p> <ul> <li>Smoke Detectors</li> <li>Pull Stations</li> <li>Waterflow Devices</li> <li>Tamper Switches</li> </ul>
Certifications & Standards : <ul> <li>UL: S624</li> <li>FM approved</li> <li>CSFM: 7165-0075:0216</li> <li>MEA: 333-07-E</li> </ul>
Compatibility : 24 volt DC operation., 7.0 amps total 24 VDC output current., 80-character LCD display (backlit)., Adjustable waterflow discharge timer and two soak timers., Amseco, ANN-80 Remote LCD Annunciator, ANN-BUS for connection to optional devices (up to 8 total of any of the following):, ANN-I/O LED Driver, ANN-LED Annunciator Module, ANN-RLY Relay Module, ANN-S/PG Printer Module, Auto-Silence, Built-in Programmer., Cross-zone (double-interlock) capability., Designed for sprinkler standards NFPA 13, 15 and 16., Disable/Enable control per input zone and output zone., Dual hazard operation., Extensive transient protection., Faraday, FM Approved., Four programmable Style Y (Class B) output circuits - (special application power)., Gentex, History log with 256 event storage., Listed to UL Standard 864, 9th edition., Low AC voltage sense., NACs programmable for:, Outputs Programmable for:, Piezo sounder for alarm, trouble and supervisory., Real-time clock/calendar with daylight savings time control., Release Stage Sounder, Releasing circuits or NACS, Resettable and non-resettable output power., Selective Silence (horn-strobe mute), Silence Inhibit, Silenceable or Non-silenceable, Six programmable Style B (Class B) IDCs (Initiating Device Circuit)., Strobe Synchronization, Strobe Synchronization:, System Sensor, System Sensor i3 series detectors compatible., Temporal or Steady Signal, Three programmable Form-C relays., Wheelock
Package Contents : <ul> <li>MRP-2001E Fire Alarm Control Panel</li> <li>Backbox</li> <li>240 VAC Power Supply</li> <li>Technical Manual</li> <li>Instruction Sheet</li> </ul>